First prepare the positive terminal with its Regulator and Inverter cables. Then prepare the
negative terminal in the same way. To attach each terminal to the lead point of connection on
the battery, it can be opened with pliers and then forced down with a hammer. Tighten
completely with a fixed spanner or socket.
6. Connect the cables from the battery to the regulator
Following the indications on the Regulator which nominate them 1, 2; the inlets from the battery
should be connected first. This is to balance the system voltage according to the battery. Once
this is carried out the LEDs (green, orange and red) should come on one after the other,
finishing with the constant illumination of the orange LED (on the Morningstar SHS Regulators.)
Order of Regulator connections (Morningstar diagram.)
For connections to the Regulator:
- User the right size screw driver.
- First slacken the terminal screws completely
20